SHERWIN WILLIAMS CO SPRAYON DIVISION -- 00208 CUTTING OIL, LUBRICANTS RUST (SUPP DATA) -- 9150-00N074214
=====================  Product Identification  =====================

Product ID:00208 CUTTING OIL, LUBRICANTS RUST (SUPP DATA)
MSDS Date:02/01/1992
FSC:9150
NIIN:00N074214
=== Responsible Party ===
Company Name:SHERWIN WILLIAMS CO SPRAYON DIVISION
Address:6830 COCHRAN RD
City:COLON
State:OH
ZIP:44139
Country:US
Info Phone Num:800-777-2966
Emergency Phone Num:216-292-7400
CAGE:54626
=== Contractor Identification ===
Company Name:SHERWIN WILLIAMS COMPANY
Address:101 PROSPECT AVE NW
City:CLEVELAND
State:OH
ZIP:44115
Country:US
Phone:216-566-2902
CAGE:54626
Company Name:SHERWIN-WILLIAMS DIVERSIFIED BRANDS, INC.
Address:26300 FARGO AVENUE
Box:City:BEDFORD HEIGHTS
State:OH
ZIP:44146
Country:US
Phone:216-292-7400 OR 216-595-8634
CAGE:09800

=============  Composition/Information on Ingredients  =============

Ingred Name:PROPANE (PROPELLANT). VP:760.
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: 5%
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT

Ingred Name:PROPANE, 2-METHYL-; (2-METHYLPROPANE (PROPELLANT)). VP:760.
CAS:75-28-5
RTECS #:TZ4300000
Fraction by Wt: 5%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:PETROLEUM DISTILLATES. VP:2.
CAS:64742-96-4
Fraction by Wt: 18%
OSHA PEL:100 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

Ingred Name:MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED (SEVERE)
    HEAVY NAPHTHENIC; (PETROLEUM OIL)
CAS:64742-52-5
RTECS #:PY8035001
Fraction by Wt: 68%
OSHA PEL:5 MG/M3 (MFR)
ACGIH TLV:5 MG/M3 (MFR)

Ingred Name:VOLATILE ORGANIC COMPOUNDS: 28% BY WT EXCLUDING FEDERALLY
    EXEMPT SOLVENTS.
RTECS #:9999999VO

Ingred Name:OTHER PREC:PROCS. CONTENTS UNDER PRESS. DO NOT PUNCTURE,
    INCIN/EXPOSE TO TEMP >120F. HEAT FROM SUNLIGHT, (ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6:RADIATORS, STOVES, HOT WATER & OTHER HEAT SOURCES
    COULD CAUSE CNTNR TO BURST. DO NOT TAKE INTERNALLY. KEEP (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:OUT OF REACH OF CHILDREN. USE ONLY W/ADEQ VENT. AVOID
    BRTHG VAP & SPRAY MIST. AVOID CONT W/SKIN & EYES. (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8:THIS COATING MAY CONTAIN MATLS CLASSIFIED AS NUISANCE
    PARTICULATES WHICH MAY BE PRESENT AT HAZ LEVELS ONLY(ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:DURING SANDING/ABRADING OF DRIED FILM. IF NO SPECIFIC
    DUSTS ARE LISTED IN INGS SECTION, APPLIC LIMS FOR (ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10:NUISANCE DUSTS ARE ACGIH TLV 10 MG/M3 (TDUST), OSHA
    PEL 15 MG/M3 (TDUST), 5 MG/M3 (RESPIRABLE FRACTION).
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EXPOS MAY BE BY INHAL &/OR SKIN/EYE
    CONT, DEPENDING ON CNDTNS OF USE. TO MIN EXPOS, FOLLOW RECS FOR
    PROPER USE, VENT & PERSONAL PROT EQUIP. ACUTE:IRRIT OF EYES, SKIN &
    RESP SYS. MAY CAUSE NERV SYS DEP RESS. EXTREME OVEREXP MAY RSLT IN
    UNCON& POSS DEATH. HDCH, DIZZ, NAUS & LOSS OF COORD ARE INDICATIONS
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:OF EXCESSIVE EXPOS TO VAPS/SPRAY
    MISTS. REDNESS & ITCH/BURNING SENSATION MAY INDICATE EYE/EXCESSIVE
    SKIN EXPOS. CHRONIC:PRLNG OVEREXP TO SOLV INGS MAY CAUSE ADVERSE
    EFTS TO LIVER, URINARY, BL OOD-FORMING, CVS & REPRO SYS. RPTS
    HAVEASSOC RPTD & PRLNG OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS
    DMG. (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
    QUIET. SKIN:WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER. REMOVE
    CONTAMINATED CLOTHING & LAUNDER BEFORE RE-USE. EYES:FLUSH W/LARGE
    AMOUNTS OF	WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION.
    INGEST:NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. DO
    NOT INDUCE VOMITING. GIVE SEVERAL GLASSES OF WATER. SEEK MEDICAL
    ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:<0F,<-18C
Lower Limits:0.7%
Upper Limits:12.8%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
    WATER SPRAY MAY BE INEFT. IF WATER IS USED, FOG NOZZ ARE PREF.
    WATER MAY BE USED TO COOL CLSD CNTNRS TO (SUPDAT)
Unusual Fire/Explosion Hazard:EXTREMELY FLAMMABLE. CLOSED CONTAINERS
    MAY EXPLODE (DUE TO BUILD-UP OF PRESSURE) WHEN EXPOSED TO EXTREME
    HEAT.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
    REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DOL STOR CATEGORY-1A. CONTENTS ARE
    EXTREMELY FLAMM. KEEP AWAY FROM HEAT, SPKS & OPEN FLAME. VAPS WILL
    ACCUM READILY & MAY IGNITE EXPLOSIVELY.
Other Precautions:DURING USE & UNTIL ALL VAPS ARE GONE:KEEP AREA
    VENTED; DO NOT SMOKE; EXTING ALL FLAMES, PILOT LIGHTS & HEATERS;
    TURN OFF STOVES, ELEC TOOLS & APPLIANCES & ANY OTHER SOURCES OF
    IGNIT. CONSULT NFPA CODE . USE APPRVD BONDING & GROUNDING (ING 6)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
    APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED NIOSH
    APPROVED ORGANIC VAPOR/PARTICULATE RESPIRATOR FOR PROTECTIONS
    AGAINST INGREDIENTS.
Ventilation:LOCAL EXHAUST PREFERABLE. GENERAL EXHAUST ACCEPT IF EXPOS
    TO INGS IS MAINTAINED BELOW APPLIC EXPOS LIMS. REFER (SUPDAT)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:PREVENTATIVES & MAINTENANCE PRODUCTS - 3. FIRE
    FIGHT PROC:PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN EXPOS TO
    EXTREME HEAT. EFTS OF OVEREXP:INTENTIONAL MISUSE BY DELIB CO NC &
    INHAL CONTENTS CAN BE HARMFUL/FATAL. VENT:TO OSHA STDS 1910.94,
    1910.107, 1910.108.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:<395F,<202C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:>75

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE, CARBON
    MONOXIDE, OXIDES OF METALS IN INGREDIENTS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WASTE FROM THIS PROD MAY BE HAZ AS DEFINED UNDER
    THE RCRA (40 CFR 261). WASTE MUST BE TESTED FOR IGNITABILITY TO
    DETERMINE APPLIC EPA HAZ WASTE NUMBERS. DO NOT INCIN. DEPRESSURIZE
    CNTNR. DISP OF I/A/W  FED, STATE & LOC REGS REGARDING POLLUTION.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.